These valves consist of a main valve and a pilot valve. The pilot valve senses the system pressure and controls the opening and closing of the main valve. When the system pressure exceeds a set limit, the pilot valve opens, causing the main valve to release the excess pressure. This arrangement allows for more accurate pressure control and quicker response times.